TIE Security Systems
TIE high security modem (Model 848)
Installation
- Obtain from the telephone company a voice grade dedicated telephone line. Signal levels
will not exceed minus 6dbm.
- Connect transmitter power, control and telephone
terminals as shown. If polarity reversing control voltages are not available for terminals 1
and 2, the TIE transmitter can be controlled by pulling screw
terminals 6 and 7 to minus (-) DC of the power supply voltage (terminal 7 for normal,
terminal 6 for alarm). A jumper or a closing relay to minus (-) DC could be used or an
opening relay from plus (+) voltage to the terminal with a 3K resistor to minus (-) DC.
Terminal 6 (alarm with override terminal 7. Listen to the telephone line with the earphone to
assure that the signal is present.
- At the receiver location listen to the telephone line with an earphone to assure that the
signal has traversed the telephone line.
- Connect receiver power, telephone line and relays as
shown. The relays are internally connected to the DC power and resistors as shown to provide
a line reversal type of indication.
Specifications
Transmitter - Electrical Characteristics
| Model 848 |
Min. |
Max. |
Units |
| DC Power Voltage |
6 |
14 |
Volts |
| DC Power Current |
15 |
50 |
mA |
| Control Voltage |
4 |
30 |
VDC |
| Control Current |
4 |
60 |
mA |
| Output Impedance |
|
620 |
OHMS |
| Normal: |
Current into Terminal 1 and out 2 |
Pulsed Tone |
| Alarm: |
Current into Terminal 2 and out 1 |
Continuous Tone |
| Trouble: |
No control current |
No Signal |
Output Signal Voltage: 0.18 volts RMS
(DC power should be filtered)
Receiver - Electrical Characteristics
| Model 848 |
Min. |
Max. |
Units |
| DC Power Voltage |
6 |
14 |
vDc |
| DC Power Current |
25 |
70 |
mA |
| Input signal Voltage |
0.01 |
0.35 |
VRMS |
| Relay Current |
|
500 |
mA |
| Input Impedance |
|
620 |
OHMS |
| Output Table |
Relay A |
Relay B |
| Normal Signal |
Closed |
Open |
| Alarm Signal |
Open |
Closed |
| No Signal |
Open |
Open |
Output Signal Voltage: 0.18 volts RMS
(DC power should be filtered)
Price: Model 848 - $225