  1. Obtain from the telephone company a voice grade dedicated telephone line. Signal levels will not exceed minus 6dbm.
  2. Connect transmitter power, control and telephone terminals as shown. If polarity reversing control voltages are not available for terminals 1 and 2, the TIE transmitter can be controlled by pulling screw terminals 3 and 4 to minus (-) DC of the power supply voltage (terminal 4 for normal, 3 for alarm). A jumper or a closing relay to minus (-) DC could be used or an opening relay from plus (+) voltage to the terminal with a 3K resistor to minus (-) DC. Terminal 3 (alarm) will override terminal 4. Listen to the telephone line with the earphone to assure that the signal is present.
  3. A telephone line termination resistor should be inserted across each end of the telephone line. For one TIE module this resistor should be 680 ohms; for two 1K ohms; for three, 2K ohms; for four, 3.3K ohms; for five, 5.1K ohms.
  4. At the receiver location listen to the telephone line with an earphone to assure that the signal has traversed the telephone line.
  5. Connect receiver power, telephone line and relays as shown. The relays are internally connected to the DC power and resistors as shown to provide a line reversal type of indication. These relays may be isolated by cutting the jumper lands between terminals 2,3,4, and 5 and between 6 and 7, if other types of indicators are to be used.
Model 847

Specifications

Transmitter - Electrical Characteristics

Model 847 Min. Max. Units
DC Power Voltage 6 14 Volts
DC Power Current 10 20 mA
Control Voltage 4 30 VDC
Control Current 4 60 mA
Output Impedance 3.3K   OHMS
Normal: Current into Terminal 1 and out 2 Pulsed Tone
Alarm: Current into Terminal 2 and out 1 Continuous Tone
Trouble: No control current No Signal

Output Signal Voltage: 0.35 volts RMS

(DC power should be filtered)

Receiver - Electrical Characteristics

Model 847 Min. Max. Units
DC Power Voltage 6 14 vDc
DC Power Current 30 40 mA
Input signal Voltage 0.018 0.35 VRMS
Relay Current   500 mA
Input Impedance 3.3K   OHMS
Output Table Relay A Relay B
Normal Signal Closed Open
Alarm Signal Open Closed
No Signal Open Open

(DC power should be filtered)